Top

2U L2U

Alimentatore L2U 2U

Gli alimentatori industriali Seasonic con il grado di efficienza 80 PLUS® Gold raggiungono un'efficienza del 90 % con un carico del 50 % all'ingresso di 115 V CA. Questi modelli L2U sono protetti contro i cortocircuiti, le sovratensioni e le sovracorrenti e soddisfano importanti standard EMI, EMC e di sicurezza. Si tratta di prodotti altamente affidabili, personalizzabili con cavi completamente modulari e silenziosi grazie al controllo integrato della ventola.

  • EPS 12 V
  • Completamente modulare
  • 80 PLUS Gold Certificato
  • Controllo del ventilatore: Seasonic S3FC
  • Sicurezza: CB, cUL, TUV, BSMI
  • EMI / EMC: CE, FCC, RCM
  • Dimensioni: 245 mm (L) x 100 mm (W) x 70 mm (H)

Confronta i prodotti dove acquistare

Panoramica

H1UL1UH2UL2U
80PLUS 80PLUS Gold 80PLUS Gold
Intel EPS1U v2.1 compliant Yes Yes Yes Yes
ATX 12 V v2.2 compliant Yes Yes Yes Yes
Dimensions 235 mm (L) x 100 mm (W) x 40 mm (H) 235 mm (L) x 100 mm (W) x 40 mm (H) 400 W and 460 W: 225 mm (L) x 100 mm (W) x 70 mm (H)
600 W: 270 mm (L) x 100 mm (W) x 70 mm (H)
245 mm (L) x 100 mm (W) x 70 mm (H)
DC to DC converter design No Yes No Yes
Forward converter circuit Yes No Yes No
Fully modular cables Yes Yes Yes Yes
Fixed cables No No No No
40 mm double ball bearing fan Yes Yes No No
60 mm double ball bearing fan No No Yes Yes
S3FC - including Fanless mode No Yes No Yes
S2FC - Smart and Silent Fan Control Yes No Yes No
Easy-swap connector design No No No No
Zero minimum load on 3.3 V rail Yes Yes Yes*
* Not applicable to 600 W
Yes
Short circuit protection on all outputs Yes Yes Yes Yes
Over voltage protection Yes Yes Yes Yes
Over power protection Yes Yes Yes Yes
100 % HiPot test Yes Yes Yes Yes
100 % Burn-in, high temperature cycled on/off Yes Yes Yes Yes
Safety compliance CB, cUL, TUV, CCC, BSMI CB, cUL, TUV, BSMI CB, cUL, TUV, CCC, BSMI*
* Not applicable to 600 W
CB, cUL, TUV, BSMI
EMI/EMC compliance CE, FCC, RCM CE, FCC, RCM CE, FCC, RCM*
* Not applicable to 600 W
CE, FCC, RCM

Specifiche

SS-500L2U

Specifications
Input frequency 50 / 60 Hz
Efficiency  80 PLUS Gold
Line regulation ± 1 % (typical)
Load regulation ± 5 % (typical)
Cross regulation ± 5 % (typical)
MTBF, full load @ 25 °C ambient (excl. DC fan) > 100,000 hours
Active Power Factor Correction 99 % (typical)
DC Outputs
+3.3 V +5 V +12 Combined -12 V +5 Vsb Total continuous power Input Type
20 A 20 A 40 A 0.3 A 2.5 A 500 W 100–240 VAC
100 W (max.) 480 W 3.6 W 12.5 W